HPLC Systems from Knauer

AZURA® Analytical UHPLC, HPLC & Educational Systems

AZURA® Preparative HPLC Systems - 50 ml/min

AZURA® Prep Pilot HPLC Systems - 100 ml/min

AZURA® Prep Pilot HPLC Systems - 250 ml/min

AZURA® Prep Pilot HPLC Systems - 500/1000 ml/min

AZURA® Analytical UHPLC, HPLC & Educational Systems

 

AZURA® UHPLC, HPLC & Educational systems

 

  • Isocratic, binary high pressure gradient or quaternary low pressure gradient pump
  • Pump heads allowing flow rates up to 10 ml/min at 700 bar or 1000 bar up to 2 ml/min
  • Autosampler with 0.1 μl sample aspiration at max. 1200 bar with zero sample loss
  • Highly sensitive UVD, MWD, DAD, or RID detectors with intelligent temperature control
  • Wide range of flow cells available, including remote cells
  • Finger-tight high pressure stainless steel capillary connections “K-Connect”
  • Extensive safety features such as leak management and sensors
  • Frontal access of detector lamp and pump head for easy maintenance

 

AZURA® Preparative HPLC Systems - 50 ml/min

 

AZURA Prep Compact LC 50 iso

 

Max. flow rate: 50 ml/min

AZURA  Assistant ASM 2.1L with manual injection valve

HPLC Pump 4.1S

Variable single wavelength detection

Maximum delivery pressure [psi]: 2180

Maximum delivery pressure [bar]: 150

Maximum delivery pressure [MPa]: 15

 

 

AZURA Prep Lab LC 50 HPG

Max. flow rate: 50 ml/min

Binary Pump P 6.1L

Variable single wavelength detection

Autosampler 6.1L

Fraction Collector Foxy R1

Maximum delivery pressure [psi]: 2180

Maximum delivery pressure [bar]: 150

Maximum delivery pressure [MPa]: 15

 

AZURA® Preparative HPLC Systems - 100 ml/min

 

AZURA Prep Pilot LC 100 Iso

 

Max. flow rate: 100 ml/min

Gradient: isocratic

Maximum delivery pressure [psi]: 5800 psi

Maximum delivery pressure [bar]: 400 bar

Maximum delivery pressure [MPa]: 40 MPa

Variable single wavelength detection UV/VIS

Injection: feed-pump

Fractionation: multi-position valve

 

 

AZURA Prep Pilot LC 100 LPG

 

Max. flow rate: 100 ml/min

Gradient: LPG

Maximum delivery pressure [psi]: 5800 psi

Maximum delivery pressure [bar]: 400 bar

Maximum delivery pressure [MPa]:40 MPa

Variable single wavelength detection UV/VIS

Injection: manual injection

Fractionation: multi-position valve

 

 

AZURA Prep Pilot LC 100 HPG

 

Max. flow rate: 100 ml/min

Gradient: HPG

Maximum delivery pressure [psi]: 5800 psi

Maximum delivery pressure [bar]: 400 bar

Maximum delivery pressure [MPa]: 40 MPa

Variable single wavelength detection UV/VIS

Injection: feed-pump

Fractionation: multi-position valve

 

AZURA® Preparative HPLC Systems - 250 ml/min

 

AZURA Prep Pilot LC 250 Iso

 

Max. flow rate: 250 ml/min

Gradient: isocratic

Maximum delivery pressure [psi]: 2900 psi

Maximum delivery pressure [bar]: 200 bar

Maximum delivery pressure [MPa]: 20 MPa

Variable single wavelength detection UV/VIS

Injection: feed-pump

Fractionation: multi-position valve

 

 

AZURA Prep Pilot LC 250 LPG

 

Max. flow rate: 250 ml/min

Gradient: LPG

Maximum delivery pressure [psi]: 2900 psi

Maximum delivery pressure [bar]: 200 bar

Maximum delivery pressure [MPa]: 20 MPa

Detector: Variable single wavelength detection UV/VIS

Injection: manual injection

Fractionation: multi-position valve

 

 

AZURA Prep Pilot LC 250 HPG

 

Max. flow rate: 250 ml/min

Gradient: HPG

Maximum delivery pressure [psi]: 2900 psi

Maximum delivery pressure [bar]: 200 bar

Maximum delivery pressure [MPa]: 20 MPa

Detector: Variable single wavelength detection UV/VIS

Injection: feed-pump

Fractionation: multi-position valve

 

AZURA® Preparative HPLC Systems - 500/1000 ml/min

 

AZURA Prep Pilot LC 500 Iso

 

Max. flow rate: 500 ml/min

Gradient: LPG

Maximum delivery pressure [psi]: 2900 psi

Maximum delivery pressure [bar]: 200 bar

Maximum delivery pressure [MPa]: 20 MPa

Detector: Variable single wavelength detection UV/VIS

Injection: manual injection

Fractionation: none

 

 

AZURA Prep Pilot LC 1000 LPG

 

Max. flow rate: 1000 ml/min

Gradient: LPG

Maximum delivery pressure [psi]: 730 psi

Maximum delivery pressure [bar]: 50 bar

Maximum delivery pressure [MPa]: 5 MPa

Detector: Variable single wavelength detection UV/VIS

Injection: LPG channel

Fractionation: multi-position valve

 

 

AZURA Prep Pilot LC 1000 HPG

 

Max. flow rate: 1000 ml/min

Gradient: HPG

Maximum delivery pressure [psi]: 730 psi

Maximum delivery pressure [bar]: 50 bar

Maximum delivery pressure [MPa]: 5 MPa

Detector: Variable single wavelength detection UV/VIS

Injection: automatic injection

Fractionation: Foxy R2 fraction collector

 