Detectors from Knauer
Detector type : Variable single wavelength UV detector
Operation Area : Analytical HPLC, Preparative HPLC, FPLC
Detection channels : 1
Wavelength range : 190 - 500 nm
Linearity : > 2.0 AU at 270 nm (ASTM E1657-98)
AZURA UV/VIS Detector UVD 2.1L
Detector type : Variable single wavelength UV detector
Operation Area : Analytical HPLC, Preparative HPLC
Detection channels : 1
Wavelength range : 190 - 750 nm
Linearity : > 2.0 AU at 270 nm (ASTM E1657-98)
Detector type : Variable multiwavelength detector
Operation Area : Analytical HPLC, Preparative HPLC, Analytical UHPLC, FPLC
Detection channels : 8 (Digital)/4 (Analog)
Wavelength range : 190 - 700 nm
Linearity : > 2.0 AU at 274 nm
Detector type : Diode array detector
Operation Area : Analytical HPLC, Preparative HPLC, Analytical UHPLC, FPLC
Detection channels : 8 (Digital)/4 (Analog)
Wavelength range : 190 - 700 nm
Number of diodes : 256
Linearity : > 2.0 AU at 274 nm
Detector type : Diode array detector
Operation Area : Analytical HPLC, Preparative HPLC, Analytical UHPLC, FPLC
Detection channels : 8 (Digital)/4 (Analog)
Wavelength range : 190 - 1000 nm
Number of diodes : 1024
Linearity : > 2.5 AU at 274 nm
AZURA Refractive Index Detector RID 2.1L
Detector type : Refractive index detector
Operation Area : Analytical HPLC
Detection channels : 1
Linearity : > 1000 µRIU
AZURA Refractive Index Detector RID 2.1L HighFlow
Detector type : Refractive index detector
Operation Area : Preparative HPLC
Detection channels : 1
Linearity : > 4000 µRIU
BlueShadow UV/VIS Detector 40D
Detector type : Variable single wavelength UV detector
Operation Area : Analytical HPLC, Preparative HPLC, FPLC
Detection channels : 1
Wavelength range : 190 - 750 nm
Linearity : > 2.0 AU at 270 nm (ASTM E1657-98)
Available with fibre optics cabling
BlueShadow UV/VIS Detector 50D
Detector type : Variable multiwavelength detector
Operation Area : Analytical HPLC, Preparative HPLC, FPLC
Detection channels : 4
Wavelength range : 190 - 750 nm
Linearity : > 2.2 AU at 270 nm (ASTM E1657-98)
AZURA Conductivity Media CM 2.1S
Detector type : Conductivity monitor
Operation Area : Preparative HPLC, FPLC
Measurement range: 0.1 – 999 mS/cm
pH measurement: 2-12
Flow cell volume: 10 ml or 100 ml
Conductivity Detector CDD-10 Avp
Detector type : Polarimetric detector
Operation Area : Analytical HPLC
Detection channels : 1
Fluorescence Detector RF-20 Axs
Detector type : Fluorescence detector
Operation Area : Analytical HPLC, Analytical UHPLC, FPLC
Detection channels : 1
Wavelength range : 200 - 650 nm
Fluorescence Detector RF-20 Axs
Detector type : Fluorescence detector
Operation Area : Analytical HPLC, Analytical UHPLC, FPLC
Detection channels : 2
Wavelength range : 200 - 750 nm
Light Scattering Detector Sedex 85LT
Detector type : Light scattering detector
Operation Area : Analytical HPLC
Detection channels : 1
Light Scattering Detector Sedex 90LT
Detector type : Light scattering detector
Operation Area : Analytical HPLC, Preparative HPLC
Detection channels : 1
Electrochemical Detector DECADE Elite SCC
Detector type : Electrochemical detector
Operation Area : Analytical HPLC
Detection channels : 1
Polarimetric Detector CHIRALYSER-MP
Detector type : Polarimetric detector
Operation Area : Analytical HPLC
Detection channels : 1