Detectors from Knauer

 

AZURA UV Detector UVD 2.1S

 

Detector type : Variable single wavelength UV detector

Operation Area : Analytical HPLC, Preparative HPLC, FPLC

Detection channels : 1

Wavelength range : 190 - 500 nm

Linearity : > 2.0 AU at 270 nm (ASTM E1657-98)

Available with fibre optics cabling

 

AZURA UV/VIS Detector UVD 2.1L

 

Detector type : Variable single wavelength UV detector

Operation Area : Analytical HPLC, Preparative HPLC

Detection channels : 1

Wavelength range : 190 - 750 nm

Linearity : > 2.0 AU at 270 nm (ASTM E1657-98)

Available with fibre optics cabling

 

AZURA Detector MWD 2.1L

 

Detector type : Variable multiwavelength detector

Operation Area : Analytical HPLC, Preparative HPLC, Analytical UHPLC, FPLC

Detection channels : 8 (Digital)/4 (Analog)

Wavelength range : 190 - 700 nm

Linearity : > 2.0 AU at 274 nm

 

 

AZURA Detector DAD 2.1L

 

Detector type : Diode array detector

Operation Area : Analytical HPLC, Preparative HPLC, Analytical UHPLC, FPLC

Detection channels : 8 (Digital)/4 (Analog)

Wavelength range : 190 - 700 nm

Number of diodes : 256

Linearity : > 2.0 AU at 274 nm

 

AZURA Detector DAD 6.1L

 

Detector type : Diode array detector

Operation Area : Analytical HPLC, Preparative HPLC, Analytical UHPLC, FPLC

Detection channels : 8 (Digital)/4 (Analog)

Wavelength range : 190 - 1000 nm

Number of diodes : 1024

Linearity : > 2.5 AU at 274 nm

 

AZURA Refractive Index Detector RID 2.1L

 

Detector type : Refractive index detector

Operation Area : Analytical HPLC

Detection channels : 1

Linearity : > 1000 µRIU

 

 

AZURA Refractive Index Detector RID 2.1L HighFlow

 

Detector type : Refractive index detector

Operation Area : Preparative HPLC

Detection channels : 1

Linearity : > 4000 µRIU

 

 

BlueShadow UV/VIS Detector 40D

 

Detector type : Variable single wavelength UV detector

Operation Area : Analytical HPLC, Preparative HPLC, FPLC

Detection channels : 1

Wavelength range : 190 - 750 nm

Linearity : > 2.0 AU at 270 nm (ASTM E1657-98)

Available with fibre optics cabling

 

 

BlueShadow UV/VIS Detector 50D

 

Detector type : Variable multiwavelength detector

Operation Area : Analytical HPLC, Preparative HPLC, FPLC

Detection channels : 4

Wavelength range : 190 - 750 nm

Linearity : > 2.2 AU at 270 nm (ASTM E1657-98)

 

 

AZURA Conductivity Media CM 2.1S

 

Detector type : Conductivity monitor

Operation Area : Preparative HPLC, FPLC

Measurement range: 0.1 – 999 mS/cm

pH measurement: 2-12

Flow cell volume: 10 ml or 100 ml

 

 

Conductivity Detector CDD-10 Avp

 

Detector type : Polarimetric detector

Operation Area : Analytical HPLC

Detection channels : 1

 

 

Fluorescence Detector RF-20 Axs

 

Detector type : Fluorescence detector

Operation Area : Analytical HPLC, Analytical UHPLC, FPLC

Detection channels : 1

Wavelength range : 200 - 650 nm

 

 

Fluorescence Detector RF-20 Axs

 

Detector type : Fluorescence detector

Operation Area : Analytical HPLC, Analytical UHPLC, FPLC

Detection channels : 2

Wavelength range : 200 - 750 nm

 

 

Light Scattering Detector Sedex 85LT

 

Detector type : Light scattering detector

Operation Area : Analytical HPLC

Detection channels : 1

 

 

Light Scattering Detector Sedex 90LT

 

Detector type : Light scattering detector

Operation Area : Analytical HPLC, Preparative HPLC

Detection channels : 1

 

 

Electrochemical Detector DECADE Elite SCC

 

Detector type : Electrochemical detector

Operation Area : Analytical HPLC

Detection channels : 1

 

 

Polarimetric Detector CHIRALYSER-MP

 

Detector type : Polarimetric detector

Operation Area : Analytical HPLC

Detection channels : 1

 